{"id":906,"date":"2026-04-03T08:21:49","date_gmt":"2026-04-03T08:21:49","guid":{"rendered":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/?p=906"},"modified":"2026-04-03T15:08:40","modified_gmt":"2026-04-03T09:38:40","slug":"what-matters-when-talking-about-sustainable-lighting","status":"publish","type":"post","link":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/sustainable-lighting\/what-matters-when-talking-about-sustainable-lighting\/","title":{"rendered":"What matters when talking about sustainable lighting?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The last decade has been a transformational time&nbsp;for the&nbsp;lighting&nbsp;industry.&nbsp;It&nbsp;was&nbsp;a time when&nbsp;LEDs&nbsp;took&nbsp;over every application,&nbsp;gearing&nbsp;their efficiency and low-cost lumens&nbsp;to&nbsp;be&nbsp;taken&nbsp;for granted.&nbsp;However, the&nbsp;phenomenal&nbsp;improvements brought by LEDs&nbsp;have led to misguided concepts in the industry that&nbsp;\u201cLEDs are efficient,\u201d triggering lighting designers to use blanket illumination.&nbsp; But now, with the climate crisis&nbsp;on the edge,&nbsp;sustainability&nbsp;has been pushed to the&nbsp;top of the agenda.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Efficiency&nbsp;does not necessarily mean&nbsp;sustainability<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lighting&nbsp;designs&nbsp;for a space&nbsp;should&nbsp;focus&nbsp;on&nbsp;where to illuminate&nbsp;and&nbsp;the illumination&nbsp;achieved in lux\/watt rather than the efficiency of the light fittings&nbsp;in terms of luminaire lumens\/watt.&nbsp; Designers have recently started&nbsp;advocating&nbsp;a combination of low-glare, precisely targeted task lighting and a general movement towards&nbsp;illuminating&nbsp;vertical surfaces over the floor.&nbsp; Light&nbsp;is directed&nbsp;exactly&nbsp;where&nbsp;it&nbsp;is&nbsp;required&nbsp;for&nbsp;carrying out&nbsp;tasks and where&nbsp;it is&nbsp;most effective for human perception;&nbsp;light&nbsp;is reduced&nbsp;everywhere else.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An&nbsp;increased emphasis on people-centric lighting designed for visual comfort&nbsp;has resulted in&nbsp;switching the focus from the floor to the vertical surfaces. The walls need to&nbsp;be illuminated&nbsp;rather than the floor to make a space feel bright.&nbsp; For example,&nbsp;the room feels three to five times brighter if&nbsp;100&nbsp;lx&nbsp;is put&nbsp;on the wall instead of the floor.\u201d<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/aceupdate.com\/wp-content\/uploads\/2025\/02\/32-4.jpg\" alt=\"ERCO_Lighting_ACE\" class=\"wp-image-37397\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Superior&nbsp;lighting with half the energy<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Historically, walls&nbsp;were not&nbsp;prioritised.&nbsp;But&nbsp;the European&nbsp;Indoor Lighting Standard&nbsp;EN 12464-1\u2019s&nbsp;latest version has&nbsp;started&nbsp;taking&nbsp;it more seriously.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In&nbsp;workplaces\/offices,&nbsp;prioritising&nbsp;to&nbsp;guide&nbsp;light where human perception requires it would dictate that light is delivered to the desktops&nbsp;or laptops.&nbsp; For instance,&nbsp;in&nbsp;a 100 sq.m&nbsp;office, desks could&nbsp;make up 20 sq.m&nbsp;of the space.&nbsp; So,&nbsp;if&nbsp;only the&nbsp;walls and&nbsp;desks were&nbsp;to be&nbsp;lit up,&nbsp;compared to uniform blanket illumination,&nbsp;almost&nbsp;half the energy&nbsp;would&nbsp;be saved&nbsp;while creating a better and brighter visual space for people.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;need for&nbsp;a design rethink&nbsp;started&nbsp;with spotlights.&nbsp; Many spotlights on the market&nbsp;today&nbsp;use a combination of chip-on-board (CoB) LED modules with reflectors.&nbsp; While&nbsp;the&nbsp;combination achieves a good luminaire lumen\/watt measurement, it generates a large, uncontrolled corona of light around the beam,&nbsp;resulting in&nbsp;wasted&nbsp;stray light.&nbsp; This&nbsp;is because&nbsp;much&nbsp;of the light from the CoB modules&nbsp;does not hit&nbsp;an optical system&nbsp;but&nbsp;gets&nbsp;scattered&nbsp;everywhere\u2014additionally, the&nbsp;very&nbsp;phenomenon&nbsp;of reflection results in a reduction of light.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/aceupdate.com\/wp-content\/uploads\/2025\/02\/34-01-2.jpg\" alt=\"ERCO_Lighting_ACE\" class=\"wp-image-37398\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ERCO solution for energy efficiency<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ERCO spotlights&nbsp;use lens systems with single high-powered chips.&nbsp; Although&nbsp;tiny,&nbsp;this&nbsp;bright point of light is much easier to control into a narrow beam of&nbsp;effective&nbsp;light.&nbsp;ERCO\u2019s&nbsp;chips&nbsp;and printed&nbsp;circuit&nbsp;boards&nbsp;are&nbsp;indigenously&nbsp;designed, and the chips are mounted&nbsp;on the boards&nbsp;before&nbsp;they&nbsp;are paired&nbsp;with&nbsp;customised&nbsp;lens designs.&nbsp;Although this&nbsp;model&nbsp;has&nbsp;only&nbsp;nominally lower lm\/W values,&nbsp;it brings up to 20&nbsp;percent&nbsp;more light to the target surface than&nbsp;its&nbsp;competitors.&nbsp; This&nbsp;means that&nbsp;planners who only look at the lm\/W values on a&nbsp;luminaire\u2019s&nbsp;technical data sheet are giving away the potential for sustainable lighting, focusing on more light&nbsp;in the target area and energy savings.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/aceupdate.com\/wp-content\/uploads\/2025\/02\/34-02-2.jpg\" alt=\"ERCO_Lighting_ACE\" class=\"wp-image-37399\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The lx\/W metric is the key to effectiveness<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The latest generation of the ERCO&nbsp;Parscan spotlight, for instance, has&nbsp;a high lumen-to-watt ratio of 105&nbsp;lm\/W, but&nbsp;it has an&nbsp;ultra-high lx\/W metric compared to other luminaires,&nbsp;a testimony to its&nbsp;effectiveness.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An&nbsp;additional important&nbsp;aspect of sustainable lighting&nbsp;is avoiding glare. If there is glare, the visual contrast is lowered, requiring&nbsp;more light&nbsp;to be added to the task.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The combination of effectively targeted light and high visual comfort&nbsp;may sound simple at first glance, but its implementation can be radical!&nbsp; With the climate crisis looming and those lumens no longer cheap, a radical approach that recalls perception-orientated lighting design with high visual comfort is probably just what is needed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em>For more details, visit:&nbsp;<a href=\"https:\/\/www.erco.com\/en\/\">https:\/\/www.erco.com\/en\/<\/a><\/em><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The last decade has been a transformational time&nbsp;for the&nbsp;lighting&nbsp;industry.&nbsp;It&nbsp;was&nbsp;a time when&nbsp;LEDs&nbsp;took&nbsp;over every application,&nbsp;gearing&nbsp;their efficiency and low-cost lumens&nbsp;to&nbsp;be&nbsp;taken&nbsp;for granted.&nbsp;However, the&nbsp;phenomenal&nbsp;improvements brought by LEDs&nbsp;have led to misguided concepts in the industry that&nbsp;\u201cLEDs are efficient,\u201d triggering lighting designers to use blanket illumination.&nbsp; But now, with the climate crisis&nbsp;on&#8230;<\/p>\n","protected":false},"author":1,"featured_media":921,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[118,112,115],"tags":[],"class_list":["post-906","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-light-experts","category-sustainable-lighting","category-technology"],"_links":{"self":[{"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/posts\/906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/comments?post=906"}],"version-history":[{"count":1,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/posts\/906\/revisions"}],"predecessor-version":[{"id":908,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/posts\/906\/revisions\/908"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/media\/921"}],"wp:attachment":[{"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/media?parent=906"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/categories?post=906"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/itmgroupmedia.com\/demo\/acelightingupdate\/wp-json\/wp\/v2\/tags?post=906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}